====== UPS Setup ======
===== Installing NUT for the OpenUPS =====
$ sudo aptitude install nut
Add the following to /etc/nut/ups.conf:
[openups]
driver = usbhid-ups
port = auto
desc = "OpenUPS"
And comment out the line ''maxretry = 3''.
Try if it works:
$ sudo upsdrvctl start
Then, edit ''/etc/nut/nut.conf'' such that the last line reads
MODE=standalone
Finally reboot and run
$ sudo upsc openups@localhost
This should display information about the connected UPS. Check the ''device.model'' parameter and make sure that it is OPEN-UPS
==== Open UPS Default Settings By Battery ====
To load these parameters, you will need to install the **[[http://www.mini-box.com/OpenUPS | Windows tool]]** provided by Mini-Box. When you run it, you should see something like this:
{{:cs:ups_setup:openups_settings.png?400|}}
By switching to the settings submenu, you will be able to load the parameters through the **All parameters: File ===> OpenUPS (settings.ini)**. Use the correct settings file from below for your battery.
If you have need to update these files, please send the request to the [[slack>it|IT Channel]]
=== LiFePo4 3 cell 9.9V 4200 mAh ===
{{ :cs:ups_setup:zippy_settings.7z |}}