Line 148: Line 148:
 | threshold ​ | unsigned int | Sets the HydroZynq ping ADC threshold value. | | threshold ​ | unsigned int | Sets the HydroZynq ping ADC threshold value. |
 | debug      | unsigned int | If data is 0, HydroZynq debug mode is disabled. Otherwise, debug mode is enabled. | | debug      | unsigned int | If data is 0, HydroZynq debug mode is disabled. Otherwise, debug mode is enabled. |
 +| frequency ​ | unsigned int | Specifies target pinger frequency. May be 25000, 30000, 35000, or 40000. Units are Hz. |
 +| post_ping_duration_us | unsigned int | The number of microseconds after ping threshold to truncate the signal to. //Default: 50 us//
 +| pre_ping_duration_us | unsigned int | The number of microseconds before ping threshold to truncate the signal to. //Default: 100 us//|
 +| filter ​    | unsigned int | If data is 0, IIR filtering is disabled. Otherwise, filter is enabled. //Default: disabled.// |
  
 In debug mode, the HydroZynq records for 2.1 seconds, dumps all 2.1 seconds of data to the data stream port, and repeats. No correlations are performed and no result is sent. In debug mode, the HydroZynq records for 2.1 seconds, dumps all 2.1 seconds of data to the data stream port, and repeats. No correlations are performed and no result is sent.