ee:hydrophones:start [2018/03/20 04:53] Ryan Summers [Communication] |
ee:hydrophones:start [2018/03/20 04:54] Ryan Summers [Communication] |
||
---|---|---|---|
Line 149: | Line 149: | ||
| debug | unsigned int | If data is 0, HydroZynq debug mode is disabled. Otherwise, debug mode is enabled. | | | debug | unsigned int | If data is 0, HydroZynq debug mode is disabled. Otherwise, debug mode is enabled. | | ||
| frequency | unsigned int | Specifies target pinger frequency. May be 25000, 30000, 35000, or 40000. Units are Hz. | | | frequency | unsigned int | Specifies target pinger frequency. May be 25000, 30000, 35000, or 40000. Units are Hz. | | ||
- | | post_ping_duration_us | unsigned int | The number of microseconds after ping threshold to truncate the signal to. //Default: 50 us// | + | | post_ping_duration_us | unsigned int | The number of microseconds after ping threshold to truncate the signal to. //Default: 50 us//| |
| pre_ping_duration_us | unsigned int | The number of microseconds before ping threshold to truncate the signal to. //Default: 100 us//| | | pre_ping_duration_us | unsigned int | The number of microseconds before ping threshold to truncate the signal to. //Default: 100 us//| | ||
| filter | unsigned int | If data is 0, IIR filtering is disabled. Otherwise, filter is enabled. //Default: disabled.// | | | filter | unsigned int | If data is 0, IIR filtering is disabled. Otherwise, filter is enabled. //Default: disabled.// | |